A glycol chiller keeps beer cold as it travels through a long-draw draft system, using a mix of water and food-grade propylene glycol circulating alongside the beer line from keg to tap. The QuickPro 4000G handles mid to long-distance runs, up to 250 ft, without losing temperature along the way.
A digital thermostat holds the glycol at your set temperature, and the compressor has enough output to keep performance steady even near the far end of that range. That kind of reach means a stadium concession, a large restaurant, or any multi-tap venue can run everything off one central cooler instead of placing a chiller at every dispensing point.
Works alongside standard trunkline and the rest of your draft beer parts. Sending beer to a draft beer tower further out than usual? Run your numbers through our glycol chiller sizing calculator to confirm the QuickPro 4000G covers your distance.
QuickPro 4000G - 4000 BTUs - USA Only |
|
| Maximum Distance - ft | 250 |
| BTU Capacity - BTU/H | 4000 |
| Dimensions - WxDxH - in | 18.1x17.1x27.3 |
| Weight - Gross/Net - lb | 144/138 |
| Glycol Tank Capacity - Gal | 2 |
| Compressor Power - HP | 1/2 |
| Plug Type - NEMA# | 5-15P |
| Amperage - A | 12 |
| Voltage - V | 115 |
| Frequency - Hz | 60 |
| Pump - Type | Rotary Vane |
| Pump Flow Rate - GP/H | 80 |
| Preinstalled Pumps | 1 |
| Additional Pumps | 0 |
| Refrigerant | R290 |
| Refrigerant Charge - G (Oz) | 150 (5.29) |
| Power Cord Length - ft | 6 |
| Inlet / Outlet Barb - in | 3/8 |
| Operating Ambient Temperature - °F | 60-90 |
| Recommended Clearance around Unit - in | 12 |
| Recommended Glycol Mixture - Glycol / Water | 40/60 |
Note: Installation of this item must be handled by a qualified installer in order to qualify for product return and/or warranty coverage. Qualified Installer - Defined as a licensed professional who charges a fee for his services, and possesses a business license, contractor's license, and/or resale permit. Common examples of a "qualified installer" include Electrician; General Contractor; Heating and Air Conditioning Specialist.
Glycol Chiller BTU Sizing Calculator
Determine the correct chiller capacity for your long draw draft beer system.
| Faucets × 100 — heat load per faucet | BTU/ft — from trunkline at dispense temp |
| Base Load — overhead (default 500 BTU/hr) | Safety Factor — 1.25× recommended |
| Questions about your system? (866) 590-9299 · sales@beveragecraft.com |
Get a Quote → |